Description
The Memory Battery Sub (MBS003,004) is used in conjunction with the Memory Logging Tool (MLT002). The tool houses the battery pack.
Ratings & Dimensions
Diameter |
1.69 in (43.0 mm) |
Max temperature* |
392°F (200°C) |
Max pressure |
15,000 psi (103.4 mPa) |
Materials |
Corrosion resistant materials used throughout |
Hardware Characteristics
Combinability |
All HD tools (RADii, iQ, PL, RAS etc) |
Upper Connection |
15/16” UN thread |
Electrical Specifications
MBS003 |
MBS004 |
|
Battery pack |
5 x C cell |
5 x CC cell |
Nominal |
19.5 V |
|
Cell voltage |
3.9 V |
|
Chemistry |
Lithium Sulfuryl Chloride |
|
Discharge |
3% per year at 77°F (25°C) |
|
Temperature Range |
-4°F to 320°F (-20°C to 160°C) |
* Batteries is not included.
* Temperature range is determined by the battery pack. Typical battery packs are rated between -4°F to 320°F (-20°C to 160°C).
Version Control: 2021.11.11
On-line specifications are for REFERENCE ONLY and subject to change without notice. DO NOT USE FOR FIELD OPERATIONS.