Description
The XY Caliper Tool (XYC002) provides a continual measurement of independent X & Y internal tubular diameters by means of measurement arms set at 90° apart. The tool closes to 1 11/16” and opens to 9” allowing use in both tubing and casing up to 9 5/8” OD.
As with all HD downhole products, internal temperature is recorded to non-volatile memory to enable detailed temperature exposure records to be maintained.
Ratings & Dimensions
Max temperature |
350°F (177°C) |
Max pressure |
15,000 psi (103.4 mPa) |
Outer diameter |
1.69 in (43.0 mm) |
Length |
44.6 in (1134.0 mm) |
Weight |
15.5 lb (7.0 kg) |
Materials |
Corrosion resistant materials used throughout |
Measurements
Resolution |
0.005 in (0.127 mm) |
Accuracy |
Better than 0.1 in (2.54 mm) |
Measurement Range |
Tool OD to 9.0 in (228.6 mm) |
Hardware Characteristics
Combinability |
all HD tools (RADii, iQ, PL, RAS etc) |
|
Tool positioning |
Centralized |
|
Acquisition mode |
Real-time with TCU |
Memory with MLT |
Electrical Specification
Current |
7 mA @ 50 V |
12 mA @ 19 V |
Applications
Identification of defects such as scale build up, corrosion or deformation |
Identification of completion items |
Volumetric flow rate calculations & corrections |