Description
The small/medium diameter RADii® HD Segmented Cement Bond Tool uses a single ceramic transmitter, an eight segment receiver at 3 ft. and a single receiver at 5 ft. spacing. The segmented receiver generates a cement map which enables identification of cement channeling while the single receiver generates the traditional cement bond log (CBL) and a variable-density log (VDL).
Ratings & Dimensions
Max Temperature |
350°F (177°C) |
Maximum Pressure |
15,000 psi (103.42 MPa) |
Outer Diameter |
1.69 in (43.0 mm) |
Length |
8.60 ft (2.62 m) |
Weight |
41 lb (18.60 kg) |
Tensile Strength |
Tension & Compression: 15,000 lb Torque: 150 ft-lb |
Materials |
SST |
Measure Points |
Amplitude, TT: 4.3 ft (1.3 m) VDL, Signature: 3.3 ft (1.0 m) |
Min/Max Csg/Tbg OD |
Min: 2.38 in ( 60.45 mm) | Max: 7.50 in ( 190.50 mm) |
Borehole Conditions
Borehole Fluids |
Salt, Fresh and Oil |
Tool Positioning |
Centralized with one each centralizer above and below |
Hardware Characteristics
Source Type |
One piezoelectric crystal fired at 20 kHz, 50 msec intervals |
Sensor Type |
Omni Receiver: One 20 kHz piezoelectric Radial Receiver: One 8 segment 20 kHz piezoelectric |
Fire Rate |
20/sec |
Waveform |
Analog: 3 ft (.9 m), 5 ft (1.5 m), Digital: Telemetry Data |
Record Time |
1300μs for each receiver, 250 μs for each sector |
Connections |
Top: GOI box Bottom: GOI pin |
Combinability |
GR, CCL, ProMac, iQ, Temperature |
Acquisition Mode |
SRO w/ TCU Mem w/ MLT |
Electrical Specification
Current |
38 mA @ 130V |
Version Control: 2021.11.11
On-line specifications are for REFERENCE ONLY and subject to change without notice. DO NOT USE FOR FIELD OPERATIONS.