Description
The 4-segment receiver of the iQ™ Magnetic Properties Tool (PTX) measures the casing in 90o sections (quadrants). The tool produces a magnetic field that opposes the primary field casing attenuation and phase shift. The magnitude of the measured phase shift is a function of the electrical conductivity, magnetic permeability and metal thickness of the field being measured. Multiple coil spacing and frequencies control the depth of investigation and measure the electromagnetic properties of the casing, that yield a quantitative casing thickness and internal diameter measurements.
Ratings & Dimensions
Max Temperature |
350°F (177°C) |
Maximum Pressure |
20,000 psi (138 MPa) |
Outer Diameter |
2.75 in (69.85 mm) |
Length |
75.0 in (1905.0 mm) |
Weight |
70.0 lb (31.75 kg) |
Csg/Tbg OD |
Min: 3.5 in (89.0 mm) Max: 7.0 in (178.0 mm) |
Tensile Strength |
Tension: 15,000 lb Compression: 15,000 lb |
Measure Points |
Casing Thickness: 24.5 in (639 mm) |
Borehole Conditions
Tool Positioning |
Centralized |
Logging Speed |
Recommended: 30 ft (9.1 m) /min Max: 60ft (318.2 m) /min |
Hardware Characteristics
Source Type: |
Single and multi frequency AC coils |
Sensor Type |
Azimuthal thickness gauge with quadrant sensitivity Multi-frequency caliper and casing properties 3-axis accelerometer for tool orientation |
Connections |
E-Line ‘GO’ Type |
Combinability |
GR, CCL, MAC, Radii Bond Tool |
Electrical Specification
Current |
+ 45 mA @ 130V |
Measurements
Casing Thickness |
Casing Caliper |
|
Principle |
Remote-field EC |
Near-field EC |
Range |
0 to 1.50 in |
3.50 to 7.00 in |
Azimuthal Resolution |
4 sectors |
NA |
Vertical Resolution |
1.56 in |
1.00 in |
Sensitivity |
1% (2 inch through-hole) |
1% |
Accuracy |
±1% |
|
Primary Curves |
Casing & differential thickness |
Casing ID |
Secondary Curves |
3-axis accelerometer, internal temperature, casing electrical properties |
Calibration
Primary & Wellsite |
Sections of API casing in different weights |
Version Control: 2021.12.16
On-line specifications are for REFERENCE ONLY and subject to change without notice. DO NOT USE FOR FIELD OPERATIONS.