Description
The Memory Logging Tool (MLT002) enables use of all HD platform logging tools without the use of an electric line cable. Tool string power is derived from a suitable battery pack housed in a Memory Battery Sub (MBS003,004).
Ratings & Dimensions
Max temperature* |
350°F (177°C) |
Max pressure |
15,000 psi (103.4 mPa) |
Outer diameter |
1.69 in (43.0 mm) |
Length |
28.4 in (721 mm) |
Weight |
10.8 lb (4.9 kg) |
Materials |
Corrosion resistant materials used throughout |
Hardware Characteristics
Combinability |
All HD tools (RADii, iQ, PL, RAS etc) |
Electrical Specification
Voltage |
12 – 50 V DC |
Current Consumption |
Load dependent (5 mA standby) |
Sample rate |
User selectable from 20m Sec |
Download time |
Typically > 4MB / minute |
Memory size |
1 GB |
* Temperature range is determined by the battery pack. Typical battery packs are rated between -4°F to 320°F (-20°C to 160°C).
Version Control: 2021.11.11
On-line specifications are for REFERENCE ONLY and subject to change without notice. DO NOT USE FOR FIELD OPERATIONS.