Description
The Flowmeter and Temperature Electronics (FLTE01) is used in with both the Full Bore Spinner (FBSM01) and the Fixed Cage Spinner Mechanical (FCSM01-02) range of products. A dedicated hall effect array provides ten pulses per revolution flowmeter output and a fast response PRT measures well bore temperature.
Ratings & Dimensions
Max temperature |
350°F (177°C) |
Max pressure |
15,000 psi (103.4 mPa) |
Outer diameter |
1.69 in (43.0 mm) |
Length |
14.6 in (371.0 mm) |
Weight |
7.2 lb (3.3 kg) |
Materials |
Corrosion resistant materials used throughout |
Flowmeter Measurements
Output |
10 pulses per revolution |
Maximum RPS |
200 |
Resolution |
2 ft (0.61 m) /min in water |
Accuracy |
+/- 2 ft (0.61 m) /min in water |
Velocity Max |
4,000 ft (1,219.2 m) /minute with 4.0 in (10.16 cm) pitch spinner |
Temperature Measurements
Range |
-40 to 350°F (-40 to 177°C) |
Resolution |
0.006°F (0.003°C) |
Accuracy |
0.9°F (0.5°C) |
Linearity |
0.5°F (0.15°C) |
Response Time |
~ 0.5 seconds |
Hardware Characteristics
Combinability |
All HD tools (RADii, iQ, PL, RAS, etc) |
|
Acquisition Mode |
Real-time (with TCU) |
Memory (with MLT) |
Electrical Specifications
Voltage |
50V DC |
19V DC |
Current |
7 mA |
16 mA |
Applications
Production logging flow & injection profiling |
Conventional temperature logging |
Leak detection, gas inflow points, top of cement |
Basic “Fracture Height” determination |
Flow behind pipe |
Version Control: 2021.11.17