Description
The Gamma Ray & Casing Collar Locator (GCL003) is a combined Gamma Ray & CCL tool which provides a passive measurement of gamma radiation by means of a Sodium Iodine Scintillation Detector and identifies changes of metal thickness by means of a collar locator.
Ratings & Dimensions
Max temperature |
350°F (177°C) |
Max pressure |
15,000 psi (103.4 mPa) |
Outer diameter |
2.75 in (70.0 mm) |
Length |
36.7 in (933.0 mm) |
Weight |
34.0 lb (15.6 kg) |
Measure Points |
Gamma Ray: 8.48 in (215.0 mm) Casing Collar: 28.9 in (735.0 mm) |
Materials |
Corrosion resistant materials used throughout |
Measurements
Range |
1-65,000 cps |
Resolution |
1 cps |
Accuracy |
10% |
Sensitivity |
(nominal) 1 count / API |
Hardware Characteristics
Combinability |
All HD tools (RADii, iQ, PL, RAS, etc) |
|
Acquisition Mode |
Real-time (with TCU) |
Memory (with MLT) |
Electrical Specifications
Voltage |
50V DC |
19V DC |
Current |
10 mA |
24 mA |
Version Control: 2021.12.14